Pilot Operated Check Valve

Product map

Pilot Operated Check Valve

Schematic diagram

Pilot Operated Check Valve

Dimensional drawing

PC 312

Pilot Operated Check Valve

Jack:

T-2A

Flow:

see graph

Working pressure:

35Mpa


Description:

Key words:

Hydraulic component development, hydraulic component integration, hydraulic electromechanical system design

Picture Name

Principle features

PC 312 allows the oil to flow from ① to ②, and at the same time cuts off the flow of oil in the opposite direction. When the pressure at ③ is high enough, the oil overcomes the spring pressure and pushes the spool open, and the oil will flow from ① to ②. The check valve has a hydraulic ratio of 1.8:1, which means that in order to open the valve at ③, the load pressure at ② must be maintained at least 1/1.8. Spring pressure ensures that the valve port is closed in static or unloaded conditions. A hydraulically sealed piston option is available.